Advanced Control
Showing 33–48 of 52 results
-
Advanced Control
ABB PSTX570-600-70 Softstarter, 590 FLA, 480 FLA
PSTX Series Softstart (New Advanced Range). Motor Voltage: 208 – 600V AC. Supply Voltage: 100 – 250V AC. Control Voltage: 24V DC, Supplied by Softstart or External Supply. Normal Duty: 590 FLA (Full Load Amps). Heavy Duty: 480 FLA (Full Load Amps). Includes: Removable Remote Mountable Digital Key-Pad, Integrated RS485 Modbus RTU, Anybus FieldBus Communication Slot, (1) PTC Motor Temp Input, (1) Analog Output, (3) Programmable Signal Relays, Programmable Overload Protection, and Integrated Bypass. H: 19.4″ W: 14.2″ D: 11.1″ Weight: 55.12Lbs. ** ASSOCIATED LUG KIT REQUIRED **
SKU: PSTX570-600-70 -
Advanced Control
ABB PSTX720-600-70 Softstart, 720 FLA, 590 FLA.
PSTX Series Softstart (New Advanced Range). Motor Voltage: 208 – 600V AC. Supply Voltage: 100 – 250V AC. Control Voltage: 24V DC, Supplied by Softstart or External Supply. Normal Duty: 720 FLA (Full Load Amps). Heavy Duty: 590 FLA (Full Load Amps). Includes: Removable Remote Mountable Digital Key-Pad, Integrated RS485 Modbus RTU, Anybus FieldBus Communication Slot, (1) PTC Motor Temp Input, (1) Analog Output, (3) Programmable Signal Relays, Programmable Overload Protection, and Integrated Bypass. H: 19.29″ W: 17.126″ D: 14.5″ Weight: 101.85Lbs. ** ASSOCIATED LUG KIT REQUIRED **
SKU: PSTX720-600-70 -
-
-
-
Advanced Control
Eaton S811+N37N3S Soft Starter 65mm 37a W/ Opt Inside The Delta
S811 Series Communicating Softstarter. Control Voltage: 24V DC. Load Voltage: 200 – 575V AC, 37 Amp, Non-Combination, 65 mm Frame Size. 15-Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40 Degrees Celcius. Hp Ratings: 10 @ 200V, 10 @ 230V, 20 @ 460V. Includes: Internal Solid-State Overload Protection, Run Bypass Mode and Lugs. ***Must use C-H Power Supply***
SKU: S811+N37N3S -
Advanced Control
Eaton S811+R10N3S Soft Starter 110mm 105a W/ Opt Inside The Delta
S811 Series Communicating Softstarter. Control Voltage: 24V DC. Load Voltage: 200 – 575V AC, 105 Amp, Non-Combination, 110 mm Frame Size. 15-Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40 Degrees Celcius. Hp Ratings: 25 @ 200V, 30 @ 230V, 60 @ 460V. Includes: Internal Solid-State Overload Protection, Run Bypass Mode and Lugs. ***Must use C-H Power Supply***
SKU: S811+R10N3S -
Advanced Control
Eaton S811+R13N3S Soft Starter 110mm 135a W/ Opt Inside The Delta
S811 Series Communicating Softstarter. Control Voltage: 24V DC. Load Voltage: 200 – 575V AC, 135 Amp, Non-Combination, 110 mm Frame Size. 15-Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40 Degrees Celcius. Hp Ratings: 30 @ 200V, 40 @ 230V, 75 @ 460V. Includes: Internal Solid-State Overload Protection, Run Bypass Mode and Lugs. ***Must use C-H Power Supply***
SKU: S811+R13N3S -
Advanced Control
Eaton S811+T18N3S Soft Starter 200mm 180a W/ Opt Inside The Delta
S811 Series Communicating Softstarter. Control Voltage: 24V DC. Load Voltage: 200 – 575V AC, 180 Amp, Non-Combination, 200 mm Frame Size. 15-Second Ramp, 4 Starts per Hour, 300% Current Limit @ 40 Degrees Celcius. Hp Ratings: 50 @ 200V, 60 @ 230V, 125 @ 460V. Includes: Internal Solid-State Overload Protection, Run Bypass Mode. ***Must use C-H Power Supply and (2) Lug Kits***
SKU: S811+T18N3S