UPC: | 78590123402 |
Additional Information: | APPLICABLE STANDARD IEC; VOLTAGE RATING 600 VAC AT 50/60 HZ; INTERRUPT RATING 125 KILOAMPERE AT 240 VAC, 100 KILOAMPERE AT 480 VAC, 50 KILOAMPERE AT 600 VAC; WIRE SIZE 3/0 AWG TO 600 KCMIL (ALUMINUM/COPPER); FOR USE WITH PANELBOARD AND SWITCHBOARD |
Catalog Number: | RLF36120U44A |
Brand Name: | PowerPact[T] |
Type: | ELECTRONIC TRIP |
Frame Type: | R |
Number of Poles: | 3 |
Current Rating: | 1200 AMPERE |
Adjustment: | INSTANTANEOUS/LONG TIME/SHORT TIME/GROUND FAULT |
Approval: | UL, CSA |
CATALOG DESCRIPTION: | POWERPACT R-FRAME, MOLDED CASE CIRCUIT BREAKER, 600V, 1200A, 3P, 50KA |
Category: | 3 Pole Interchangeable Trip Electronic Cb Trip Units Only |
Full Technical Description: | Electronic Trip Type; UL, CSA Approval; 1200 Ampere Current Rating; 3 Pole(S); R Frame Type; Instantaneous/Long Time/Short Time/Ground Fault Adjustment; POWERPACT[T] Brand; Applicable Standard IEC; Voltage Rating 600 VAC at 50/60 Hz; Interrupt Rating 125 Kiloampere at 240 VAC, 100 Kiloampere at 480 VAC, 50 Kiloampere at 600 VAC; Wire Size 3/0 AWG to 600 kcmil (Aluminum/Copper); For Use With Panelboard and Switchboard |
Manufacturer: | Square D Co. |
Manufacturer Brand: | Square D Co. |
Product Description: | SQUARE D RLF36120U44A : MOLDED CASE CIRCUIT BREAKER 600V 1200A |
Prop 65 warning: | WARNING: THIS PRODUCT CAN EXPOSE YOU TO CHEMICALS INCLUDING: DINP, WHICH IS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, AND DIDP, WHICH IS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. FOR MORE INFORMATION GO TO WWW.P65WARNINGS.CA.GOV |
Proposition 65 Warning (CA): | WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov |
Sub-Category: | Breaker Trip Unit |
UNSPSC: | 39121616 |
UPC 12 Digit: | 785901234029 |
Unique Product Key: | 5715945 |
Interchangeable Trip Electronic CB Trip Units Only
SQUARE D RLF36120U44A : MOLDED CASE CIRCUIT BREAKER 600V 1200A
Description:
SQUARE D RLF36120U44A : MOLDED CASE CIRCUIT BREAKER 600V 1200A
SQUARE D RLF36120U44A : MOLDED CASE CIRCUIT BREAKER 600V 1200A
Technical Description:
Electronic Trip Type; UL, CSA Approval; 1200 Ampere Current Rating; 3 Pole(S); R Frame Type; Instantaneous/Long Time/Short Time/Ground Fault Adjustment; POWERPACT[T] Brand; Applicable Standard IEC; Voltage Rating 600 VAC at 50/60 Hz
UPC: 78590123402
Part Number: RLF36120U44A
Manufacturer: Square D
$30,774.40